Earth Resistance Testers » EARTH RESISTANCE TESTER MRU-200


EARTH RESISTANCE TESTER MRU-200

MRU-200 is the only meter in the market which uses all measurement methods.

Possible measurements:
  • earth resistance measurment with 2-pole, 3-pole,4-pole method,
  • impulse earth impedance measurement, three kinds of measuring impulse 4/10μs, 8/20μs, 10/350μs,
  • earth resistance measurement without disconnecting measured earths (using clamp),
  • two clamps earth resistance measurement without auxiliary test probs,
  • earth resistivity measurement,
  • continuity measurement,
  • leakage current measurement.

It allows to take the measurements of:

  • earth resistance using auxiliary electrodes,
  • earth resistance using auxiliary electrodes and clamp (for measurements of multiple earthing)
  • earth resistance using double clamps for measuring multiple earthing without underground connections,
  • impulse earth impedance (without disconnecting measured earthing),
  • ground resistivity (Wenner method),
  • current using the clamp (e.g. leakage) and flexible clamp (Rogowsky coil),
  • measurement of continuity of equipotential bondings and protective conductors (meeting the requirements of IEC 60364 - 6 - 61:2000 section 6.12.2) with auto-zero function – with current 200 mA.

Additionally:

  • measurement of resistance of auxiliary electrodes RS and RH,
  • measurement of interference voltage,
  • measurement of interference frequency,
  • measurement in the presence of interference voltage in the power network
    with frequency 16 2/3 Hz, 50 Hz, 60 Hz and 400 Hz (with automatic selection of proper frequency of measuring signal or with manual selection),
  • selection of maximum measuring voltage (25 V and 50 V)
  • introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
  • memory of 990 measurements (10 banks of 99 cells each),
  • calibration of clamp used,
  • real time clock (RTC),
  • data transmission to the computer USB and Bluetooth*,
  • indication of battery state.

*Bluetooth communication from serial number E30001

Electric security:

  • type of insulation: double, according to EN 61010 - 1 and IEC 61557
  • measurement category: CAT IV 300 V acc. to EN 61010 - 1
  • protection class acc. to EN 60529: IP54

Rated operational conditions:

  • operation temperature: -10...+50°C
  • storage temperature: -20...+70°C
  • humidity: 20...80%

Other technical data:

  • LCD display: graphic, backlighted
  • interface: USB
  • number of measurements carried out of set of batteries: > 1200
  • warranty: 24 months